Cable Connection
Last updated
Last updated
Platforms
Rekor Discover™ for Urban MobilityRekor Command™ for TransportationRekor Scout® for Public Safety© 2024 Rekor Systems, Inc. All Rights Reserved.
The lightning arrester must be installed and grounded if you install the camera outdoors.
Strong and weak current cables must be kept at least 5 cm apart from each other. When connecting the cables to the device, take care to avoid connecting strong current cables to weak current interfaces or you will damage your device.
The tail of the cable must be cut if it cannot pass through the wall, please keep the label on the tail of the cable. Please make sure to use insulating tape and waterproof tape to insulate and waterproof all tails of cable to avoid short circuits and water leakage.
Wrap all pigtail cables in insulated, waterproof, rubber tape to prevent short circuits or water damage.
Connect the ground cable to ground the device, and then connect the power cable. If crimp terminals are not used, the wire thickness cannot exceed 1.5mm2, and the length cannot exceed 25m. If crimp terminals are used, the wire can be up to 0.75mm2 for a 15 m length of wiring or up to 1.0mm2 if 20 m is required. Longer wiring is not supported. The ground impedance cannot exceed 5 ohms.
Connect the ground cable of the camera to the ground.
Twisted pair cables should be used as alarm cables. The diameter of the cable core ranges from 22 AWG to 28 AWG. The impedance of the entire cable is less than or equal to 100 ohms.
Connect the network cable. Mount the number O-ring for the waterproof connector onto the network cable port and install the remaining components of the waterproof connector in the sequence shown below. The waterproof connectors of the network cable must be secured tightly or they may come loose later.